-
TASU 100 100
mixing Safe damperExcl. Tax: €0 Incl. Tax: €0in 2-3 weeksDuct: 100 -
TASU 125 125
mixing Safe damperExcl. Tax: €0 Incl. Tax: €0in 2-3 weeksDuct: 125 -
TASU 160 160
mixing Safe damperExcl. Tax: €0 Incl. Tax: €0in 2-3 weeksDuct: 160 -
TASU 200 200
mixing Safe damperExcl. Tax: €0 Incl. Tax: €0in 2-3 weeksDuct: 200 -
TASU 250 250
mixing Safe damperExcl. Tax: €0 Incl. Tax: €0in 2-3 weeksDuct: 250 -
TASU 315 315
mixing Safe damperExcl. Tax: €0 Incl. Tax: €0in 2-3 weeksDuct: 315 -
TASU 400 400
mixing Safe damperExcl. Tax: €0 Incl. Tax: €0in 2-3 weeksDuct: 400 -
TATBU 100 230 NMF
mixing Safe tight damperExcl. Tax: €382 Incl. Tax: €462in 2-3 weeksDuct: 100 -
TATBU 125 230 NMF
mixing Safe tight damperExcl. Tax: €387 Incl. Tax: €468in 2-3 weeksDuct: 125 -
TATBU 200 230 NMF
mixing Safe tight damperExcl. Tax: €417 Incl. Tax: €504in 2-3 weeksDuct: 200 -
TATBU 250 24 NMF
mixing Safe tight damperExcl. Tax: €434 Incl. Tax: €525in 2-3 weeksDuct: 250 -
TATBU 315 230 NMF
mixing Safe tight damperExcl. Tax: €476 Incl. Tax: €575in 2-3 weeksDuct: 315 -
TATBU 315 24 NMF
mixing Safe tight damperExcl. Tax: €475 Incl. Tax: €575in 2-3 weeksDuct: 315 -
TATBU 400 230 NMF
mixing Safe tight damperExcl. Tax: €528 Incl. Tax: €639in 2-3 weeksDuct: 400 -
TATBU 400 24 NMF
mixing Safe tight damperExcl. Tax: €528 Incl. Tax: €639in 2-3 weeksDuct: 400 -
TATU 100 100
mixing Safe tight damperExcl. Tax: €0 Incl. Tax: €0in 2-3 weeksDuct: 100 -
TATU 125 125
mixing Safe tight damperExcl. Tax: €0 Incl. Tax: €0in 2-3 weeksDuct: 125 -
TATU 160 160
mixing Safe tight damperExcl. Tax: €0 Incl. Tax: €0in 2-3 weeksDuct: 160 -
TATU 200 200
mixing Safe tight damperExcl. Tax: €0 Incl. Tax: €0in 2-3 weeksDuct: 200 -
TATU 250 250
mixing Safe tight damperExcl. Tax: €0 Incl. Tax: €0in 2-3 weeksDuct: 250 -
TATU 315 315
mixing Safe tight damperExcl. Tax: €0 Incl. Tax: €0in 2-3 weeksDuct: 315 -
TATU 400 400
mixing Safe tight damperExcl. Tax: €0 Incl. Tax: €0in 2-3 weeksDuct: 400
Regulation dampers
Regulating dampers are used in HVAC systems to control the air flow volume by means of adjustable rotating blades. The regulating dampers are supplied with manual control or with control by means of 24V / 230V servo-drives. The dampers can be supplied in airtight design. The regulating dampers are manufactured circular and four-sided in all dimensions up to 2000x2000 mm. As standard, we supply regulating dampers made of galvanized sheet metal or of stainless steel and aluminium.
Alternating dampers
Alternating dampers are used in HVAC systems for the division or mixing of air of individual duct routes. Thanks to their design, they divide the air from one duct into two or vice versa, from two ducts evenly into one. The circular alternating dampers consist of one extended T-piece and two interconnected regulating dampers. Possibility of other materials: stainless steel, aluminium, aluzinc. The alternating dampers are supplied with manual control or with control by means of 24V / 230V actuators. The dampers are suitable for mixing of supply air for small ventilation or heat recovery units.
Backdraft shutters / dampers
Backdraft louvre shutters
The gravity louvre shutters are used as a duct termination element installed on the facades of buildings. The gravity louvre shutters prevent the entry of unwanted air and other materials or objects into the HVAC systems when the ventilation is switched off. We supply gravity louvre shutters for circular and four-sided ducts. Gravity louvre shutters made of plastic, aluminum or galvanized according to the customer's requests.