Select your country
Prices Inc.Tax Excl.Tax
SP200100616

TD 160/100 N T Mixvent

duct diagonal fan

time overrun
Price
Excl. Tax: €101 Incl. Tax: €123
out of sortiment

The TD 160/100 N T Mixvent diagonal duct fan is designed for installation in circular ducts. The mounting is possible in any fan position. The terminal block is located on the fan housing. The TD 160/100 N T Mixvent duct fan is suitable for use in residential buildings, offices, shopping centers, commercial buildings, etc. The TD 160/100 N T Mixvent fan is available with an overrun timer adjustable within 1 and 30 minutes.


Speed [min-1]2500
Air Flow Volume [m3/h]180
Current [A]0.16
Power [W]25
Voltage230V
Duct diameter [mm]100
Min. temperature [°C]-20
Max. temperature [°C]40
Protection IPIP44
Noise [dB(A)]24
Description

The TD T Mixvent circular diagonal duct fans with an overrun timer are designed for installation in circular ducts. The fan housing is made of high-quality tough plastic. The fans are equipped with a patented vectorial noise absorber (see construction figure). The terminal block is located on the fan housing. The easy-to-remove TD Mixvent fan motor unit is housed in an integrated mounting bracket that allows an easy wall or ceiling mounting. The TD Mixvent diagonal fans can be installed in a horizontal or vertical position. The unique design of the support bracket allows mounting or dismantling of the motor and impeller assembly without dismantling the ducting.

Housing The TD 160/100 N T Mixvent fan housing is made of high-quality tough plastic and consists of a mounting bracket for wall or ceiling mounting, a patented sound absorber and a motor. The design allows easy dismantling of the motor part, which is attached with quick-release clips.
Impeller The fan impeller is diagonal and made of plastic.
Motor The fan motor is asynchronous with squirrel cage and cannot be controlled. The motors are equipped as standard with a thermal fuse against overheating. The winding has humidity protection and insulation class B. The TD duct fan motor can be easily removed for service and maintenance.
Terminal block The fan terminal block is located on the housing and is rotatable through 360° to connect the cable from any direction.
Noise level The noise emitted by the fan is given in the tables.
Installation The fan can be mounted in any position. The housing must not transmit mechanical stresses from the ducting. It is necessary to use VBM flexible connections.
Speed control The speed control is performed by means of a two-stage controller or by changing the voltage.
Additional Information
Weight [kg] 1.4
Availability out of sortiment
Type of good fan
Design duct
Design time overrun
Manufacturer Soler & Palau
Min. temperature [°C] -20
Protection IP IP44
Download
Reviews