bathroom radial fan

ball-bearings bult-in filter for flush-mounting non-return damper time overrun
Price
Excl. Tax: €137 Incl. Tax: €166
out of sortiment

The fan KN 2 are centrifugal, suitable for ventilation of the bathroom, toilets with a drain to together ventilation ducts. Fans are equipped back valve, which is can connect more fans to the one duct. Fans are designed for mounting under the plaster, fans AP are designed for mounting on the plaster. Pressure of the fan ∅ is 80 mm. Type AP is can be connect via reduction flanges to ∅ 50 , 75, 80 or 100 mm. Housing is made of plastic in white color. Fans are suitable for transport of the air, without mechanical particles, which could cause abrasion or imbalanced of the impeller. Fan can be controlled with controllers of the speed. Fans should be stored in covered and dry warehouse. Is can be delivered fans KN 2UP/AP 100/F with fire proof.


Speed [min-1]1980
Air Flow Volume [m3/h]135
Input Power [W]42
Voltage230V
Max. temperature [°C]40
Duct diameter [mm]80
Noise [dB(A)]51
Description
Housing

The cupboard is made of ABS, color is white. Perform AP with drain in direction back, diameter of drain throat is 50 mm with add distance 75 mm ( reduction 100 mm is can be delivered). Perform UP with drain on the side, diameter of drain throat is 74 mm. The mounting is on the wall, under plaster or into the ceiling. The front grille included filter and silencer of the noise.

Impeller

The impeller is centrifugal with frontward cursed blades and it is made of galvanized sheet.

Motor

The engine is asychronous with external rotor and starter capacitor. External rotor is placed in ball bearings, which is greased to time for their life. The thermal fuse is placed in engine. Temperature resistance to 40 °C. Protection IPX5.

Terminal block

The terminal block is entry after removing the front grille.

Noise level

The noise emitted by fan is measured in distance 1m in axis fan on the side where is suction.

Installation The mounting of UP is done under plaster or to the ceiling (is necessary delivered with valve ERKF), in horizontal and vertical position. The mounting AP is done on the wall or on the ceiling ( is necessary delivered with valve ERKF). Fans is delivered in complete shape, housing is covered provisional cover and after mounting is replaced with front grille. On ask is can be delivered housing and engine, fan on one's own.
Usage This fan is suitable to use for duct in bigger size with higher pressure loss. Performance is for fans with top outlet which have a design under plaster. Design of fans on plaster with back outllet is flow lower by 25%. Fan is designed for indoor use, where is temperature from 0-40 °C, for transport clean air without particles, greasiness, exhale chemicals etc. It is also necessary to ensure that the freezing of the fan, running into him and becoming covered in it condensate water from the pipeline.
Additional Information
Weight [kg] 2.5
Availability out of sortiment
Fan colour white
Type of good fan
Design bathroom
Design ball-bearings, bult-in filter, for flush-mounting, non-return damper, time overrun
Manufacturer Red-Ring
Usage This fan is suitable to use for duct in bigger size with higher pressure loss. Performance is for fans with top outlet which have a design under plaster. Design of fans on plaster with back outllet is flow lower by 25%. Fan is designed for indoor use, where is temperature from 0-40 °C, for transport clean air without particles, greasiness, exhale chemicals etc. It is also necessary to ensure that the freezing of the fan, running into him and becoming covered in it condensate water from the pipeline.