Housing The cupboard is made of ABS, color is white. Perform AP with drain in direction back, diameter of drain throat is 50 mm with add distance 75 mm ( reduction 100 mm is can be delivered). Perform UP with drain on the side, diameter of drain throat is 74 mm. The mounting is on the wall, under plaster or into the ceiling. The front grille included filter and silencer of the noise.
Impeller The impeller is centrifugal with frontward cursed blades and it is made of galvanized sheet.
Motor The engine is asychronous with external rotor and starter capacitor. External rotor is placed in ball bearings, which is greased to time for their life. The thermal fuse is placed in engine. Temperature resistance to 40 °C. Protection IPX5.
Terminal block The terminal block is entry after removing the front grille.
Noise level The noise emitted by fan is measured in distance 1m in axis fan on the side where is suction.
Installation The mounting of UP is done under plaster or to the ceiling (is necessary delivered with valve ERKF), in horizontal and vertical position. The mounting AP is done on the wall or on the ceiling ( is necessary delivered with valve ERKF). Fans is delivered in complete shape, housing is covered provisional cover and after mounting is replaced with front grille. On ask is can be delivered housing and engine, fan on one's own. Usage This fan is suitable to use for duct in bigger size with higher pressure loss. Performance is for fans with top outlet which have a design under plaster. Design of fans on plaster with back outllet is flow lower by 25%. Fan is designed for indoor use, where is temperature from 0-40 °C, for transport clean air without particles, greasiness, exhale chemicals etc. It is also necessary to ensure that the freezing of the fan, running into him and becoming covered in it condensate water from the pipeline. - Additional Information
-
Weight [kg] 2.5 Availability out of sortiment Fan colour white Type of good fan Design bathroom Design ball-bearings, bult-in filter, for flush-mounting, non-return damper, time overrun Manufacturer Red-Ring Usage This fan is suitable to use for duct in bigger size with higher pressure loss. Performance is for fans with top outlet which have a design under plaster. Design of fans on plaster with back outllet is flow lower by 25%. Fan is designed for indoor use, where is temperature from 0-40 °C, for transport clean air without particles, greasiness, exhale chemicals etc. It is also necessary to ensure that the freezing of the fan, running into him and becoming covered in it condensate water from the pipeline. - Download
-