-25%
ILHT/6-800 MV
fire radial fanRegular Price: €5,221 €6,317
Special Price Excl. Tax: €3,916 Incl. Tax: €4,738
in 4-6 weeksAir: 24820Noise: 72 -
-25%
ILHT/6-800 CC
fire radial fanRegular Price: €5,672 €6,863
Special Price Excl. Tax: €4,254 Incl. Tax: €5,147
in 4-6 weeksAir: 25660Noise: 72 -
-25%
ILHT/6-710 MV
fire radial fanRegular Price: €4,332 €5,241
Special Price Excl. Tax: €3,249 Incl. Tax: €3,931
in 4-6 weeksAir: 19690Noise: 72 -
-25%
ILHT/6-710 CC
fire radial fanRegular Price: €4,849 €5,867
Special Price Excl. Tax: €3,636 Incl. Tax: €4,400
in 4-6 weeksAir: 18910Noise: 74 -
-25%
ILHT/6-630 MV
fire radial fanRegular Price: €3,240 €3,921
Special Price Excl. Tax: €2,430 Incl. Tax: €2,941
in 4-6 weeksAir: 12260Noise: 65 -
-25%
ILHT/6-630 CC
fire radial fanRegular Price: €3,674 €4,445
Special Price Excl. Tax: €2,755 Incl. Tax: €3,334
in 4-6 weeksAir: 11800Noise: 68 -
-25%
ILHT/6-560 MV
fire radial fanRegular Price: €2,643 €3,199
Special Price Excl. Tax: €1,983 Incl. Tax: €2,399
in 4-6 weeksAir: 8300Noise: 63 -
-25%
ILHT/6-560 CC
fire radial fanRegular Price: €3,080 €3,727
Special Price Excl. Tax: €2,310 Incl. Tax: €2,795
in 4-6 weeksAir: 7960Noise: 63 -
-25%
ILHT/6-500 MV
fire radial fanRegular Price: €2,221 €2,688
Special Price Excl. Tax: €1,666 Incl. Tax: €2,016
in 4-6 weeksAir: 6430Noise: 61 -
-25%
ILHT/6-500 CC
fire radial fanRegular Price: €2,593 €3,137
Special Price Excl. Tax: €1,945 Incl. Tax: €2,353
in 4-6 weeksAir: 6090Noise: 66 -
-25%
ILHT/6-450 MV
fire radial fanRegular Price: €1,764 €2,135
Special Price Excl. Tax: €1,323 Incl. Tax: €1,601
in 4-6 weeksAir: 5240Noise: 59 -
-25%
ILHT/6-450 CC
fire radial fanRegular Price: €2,087 €2,526
Special Price Excl. Tax: €1,566 Incl. Tax: €1,894
in 4-6 weeksAir: 4940Noise: 63 -
-25%
ILHT/6-400 MV
fire radial fanRegular Price: €1,630 €1,973
Special Price Excl. Tax: €1,223 Incl. Tax: €1,480
in 4-6 weeksAir: 3600Noise: 54 -
-25%
ILHT/6-400 CC
fire radial fanRegular Price: €1,911 €2,312
Special Price Excl. Tax: €1,433 Incl. Tax: €1,734
in 4-6 weeksAir: 3410Noise: 58 -
-25%
ILHT/6-355 MV
fire radial fanRegular Price: €1,530 €1,852
Special Price Excl. Tax: €1,148 Incl. Tax: €1,389
in 4-6 weeksAir: 2220Noise: 50 -
-25%
ILHT/6-355 CC
radial fanRegular Price: €1,791 €2,167
Special Price Excl. Tax: €1,343 Incl. Tax: €1,625
in 4-6 weeksAir: 2110Noise: 54 -
-25%
ILHT/4-560 MV
fire radial fanRegular Price: €2,772 €3,354
Special Price Excl. Tax: €2,079 Incl. Tax: €2,515
in 4-6 weeksAir: 12900Noise: 72 -
-25%
ILHT/4-560 CC
fire radial fanRegular Price: €3,194 €3,864
Special Price Excl. Tax: €2,395 Incl. Tax: €2,898
in 4-6 weeksAir: 12470Noise: 72 -
-25%
ILHT/4-500 MV
fire radial fanRegular Price: €2,439 €2,951
Special Price Excl. Tax: €1,829 Incl. Tax: €2,213
in 4-6 weeksAir: 10140Noise: 70 -
-25%
ILHT/4-500 CC
fire radial fanRegular Price: €2,810 €3,400
Special Price Excl. Tax: €2,108 Incl. Tax: €2,550
in 4-6 weeksAir: 9630Noise: 75 -
-25%
ILHT/4-450 MV
fire radial fanRegular Price: €1,936 €2,343
Special Price Excl. Tax: €1,452 Incl. Tax: €1,757
in 4-6 weeksAir: 8320Noise: 67 -
-25%
ILHT/4-450 CC
fire radial fanRegular Price: €2,260 €2,734
Special Price Excl. Tax: €1,695 Incl. Tax: €2,051
in 4-6 weeksAir: 7860Noise: 72 -
-25%
ILHT/4-400 MV
fire radial fanRegular Price: €1,627 €1,969
Special Price Excl. Tax: €1,221 Incl. Tax: €1,477
in 4-6 weeksAir: 5650Noise: 63 -
-25%
ILHT/4-400 CC
fire radial fanRegular Price: €1,908 €2,309
Special Price Excl. Tax: €1,431 Incl. Tax: €1,732
in 4-6 weeksAir: 5340Noise: 67 -
-25%
ILHT/4-355 MV
fire radial fanRegular Price: €1,511 €1,828
Special Price Excl. Tax: €1,133 Incl. Tax: €1,371
in 4-6 weeksAir: 3550Noise: 59
MUB/F
![MUB/F](https://en.ventilatory.net/media/catalog/category/mub_f_kategorie.png)
The MUB/F noise-insulated smoke extract centrifugal fans are designed for installation in four-sided or circular ducts. The MUB/F fans are suitable for transporting air up to 400°C/120 min. The fans have a rubber sealed connections on both the inlet and discharge side. By selecting the side discharge, higher air flow rates are achieved.
CHAT
![CHAT](https://en.ventilatory.net/media/catalog/category/chat.png)
The CHAT smoke extract fans are designed for HVAC applications where fire ventilation requirements are placed and where low fan noise level is applied. The CHAT fans have a radial impeller, a motor with a one-time operating temperature of 400 °C for two hours, equipped with ball bearings. The fan housing is equipped with removable panels for inspection or cleaning.
CTHT
CTVT
![CTVT](https://en.ventilatory.net/media/catalog/category/ctvt.png)
CTVT are fire roof fans designed for the heat and smoke extraction mode according to the applicable guidelines. The CTVT fans are designed to extract air at a constant temperature of 120 °C and can withstand temperatures of up to 400 °C for two hours in the event of a fire. The CTVT fans are suitable for HVAC installations where there is a risk of fire, e.g.: industrial halls, shopping centres, sports halls, etc.
CVHT
HGHT-V
![HGHT-V](https://en.ventilatory.net/media/catalog/category/hght_v.png)
HGHT-V are fire roof fans suitable for HVAC applications where their high flow rates and the possibility of using them in heat and smoke extraction mode are applicable. The HGHT-V fans have a long term resistance of 40 °C and a resistance of 400 °C for two hours or 300 °C in the heat and smoke extraction system. The fans are equipped with a non-return damper and an emergency switch located on the housing.
ILHB / ILHT
![ILHB / ILHT](https://en.ventilatory.net/media/catalog/category/ilhb_kat.png)
ILHB / ILHT are centrifugal square duct fire fans designed for extraction of hot air and smoke in case of fire (F400/120). The ILHB / ILHT square duct centrifugal fans are suitable for continuous air extraction in industrial, commercial premises and professional kitchens with air temperature up to 120 °C.
The fan casing is made of galvanized steel sheet and aluminium profiles. They are available in a standard version with the MV marking or with an integrated plenum box with the CC marking with a choice of intake and discharge. The fans can be mounted in any position preferably with the motor axis vertical or horizontal with regard to fan maintenance. The fans can also be mounted outdoors using a motor cover.
THGT
![THGT](https://en.ventilatory.net/media/catalog/category/thgt.png)
The THGT smoke extract axial fans are designed for heat and smoke extract systems and for environments with a requirement for high airflow volume. The THGT fans are supplied with differently set impeller blade angles, which are shown in the performance graphs. The motors have insulation class H due to the smoke and heat removal mode. The operating temperature of the fans is 40 °C, in a heat and smoke extract system up to 400 °C for two hours.
TJHT
DVV
![DVV](https://en.ventilatory.net/media/catalog/category/dvv.png)
The DVV roof fire fans are designed for ventilation in heat and smoke extraction mode as well as for classic ventilation. The fans can withstand temperatures of 120 °C in the long term and up to 400 °C /600 °C for two hours (in the OTK mode). The DVV fans have IE motors with built-in PTC thermistors. In the event of a fire and switching to the OTK mode, all protections and controllers must be bypassed. The fans are equipped with a service switch.
DVG
![DVG](https://en.ventilatory.net/media/catalog/category/dvg.png)
The DVG roof centrifugal fans for heat and smoke extraction as well as for normal ventilation are designed for installation on roof extensions. The design of the DVG fans is adapted for long-term operation up to 120 °C and 400 °C for two hours. The fans are available in two variants DVG-H - horizontal discharge or DVG-V - vertical discharge.
- CE certification according to EN 12101-3, 2002-6 TÜV Süd.
- Tested according to EN 12101- 3 LGAI, Barcelona.
Datasheet of the product series: ds-dvg-en.pdf
SKU | Name |
SA9995419 | DVG-V 315D4-XL-F400 |
SA9995417 | DVG-V 315D4-6-XL-F400 |
SA9995418 | DVG-V 315D4-8-XL-F400 |
SA9995420 | DVG-V 315D6-XL-F400 |
SA9995421 | DVG-V 355D4-XL-F400 |
SA9995422 | DVG-V 355D4-6-XL-F400 |
SA9995423 | DVG-V 355D4-8-XL-F400 |
SA9995424 | DVG-V 355D6-XL-F400 |
SA9995428 | DVG-V 400D4-XL-F400 |
SA9995429 | DVG-V 400D4-XS-F400 |
SA9995426 | DVG-V 400D4-6-XS-F400 |
SA9995425 | DVG-V 400D4-6-XL-F400 |
SA9995427 | DVG-V 400D4-8-XL-F400 |
SA9995431 | DVG-V 400D6-XS-F400 |
SA9995430 | DVG-V 400D6-XL-F400 |
SA9995432 | DVG-V 450D4-XL-F400 |
SA9995433 | DVG-V 450D4-6-XL-F400 |
SA9995434 | DVG-V 450D6-XL-F400 |
SA9995438 | DVG-V 500D4-XL-F400 |
SA9995439 | DVG-V 500D4-XS-F400 |
SA9995438 | DVG-V 500D4-XL-F400 |
SA9995435 | DVG-V 500D4-6-XL-F400 |
SA9995437 | DVG-V 500D4-8-XL-F400 |
SA9995441 | DVG-V 500D6-XS-F400 |
SA9995440 | DVG-V 500D6-XL-F400 |
SA9995442 | DVG-V 560D4-XL-F400 |
SA9995443 | DVG-V 560D4-6-XL-F400 |
SA9995444 | DVG-V 560D4-8-XL-F400 |
SA9995445 | DVG-V 560D6-XL-F400 |
SA9995448 | DVG-V 630D4-XL-F400 |
SA9995449 | DVG-V 630D4-XM-F400 |
SA9995450 | DVG-V 630D4-XS-F400 |
SA9995447 | DVG-V 630D4-6-XS-F400 |
SA9995446 | DVG-V 630D4-6-XL-F400 |
SA9995451 | DVG-V 630D6-XL-F400 |
SA9995186 | DVG-V 800D6-XL/F400 IE3 |
SA9995187 | DVG-V 800D6-XS/F400 IE3 |
SA9995196 | DVG-V 800D8-XL/F400 IE3 |
DVG-EC
![DVG-EC](https://en.ventilatory.net/media/catalog/category/dvg_ec.png)
The DVG-EC centrifugal energy-saving roof fans for heat and smoke extraction as well as for normal ventilation are designed for installation on roof structures. The DVG-EC fire fans are equipped with energy-saving EC motors with 0-10V speed control input. The DVG-EC fans are designed to withstand 120°C for long periods of time and 400°C for two hours. The fans are available in two variants DVG-H - horizontal discharge or DVG-V - vertical discharge. Fans with heat resistance F400/90, F300, F200 can be supplied on request.
- CE certification to EN 12101-3 BSI, UK.
- Tested according to EN 12101- 3 LGAI, Barcelona.
SKU | Name |
SA9995277 | DVG-V 355EC-XL-F400 |
SA9995278 | DVG-V 450EC-XL-F400 |
SA9995279 | DVG-V 560EC-XL-F400 |
SA9995280 | DVG-V 630EC-XM-F400 |
SA9995349 | DVG-V 710EC-XL-F400 |
SA9995281 | DVG-V 800EC-XL-F400 |
KBR/F
![KBR/F](https://en.ventilatory.net/media/catalog/category/kbr_f.png)
The KBR/F centrifugal smoke extract fans are designed for heat and smoke extraction and for common applications. The design of the fans guarantees a long term temperature resistance of 200 °C and up to 400 °C for two hours in the smoke extract mode. The fans are equipped with a hinged door on which the impeller motor is located. The fans are made of a double casing of galvanised steel sheet with thermal and noise insulation made of mineral wool.
AXC G
![AXC G](https://en.ventilatory.net/media/catalog/category/kat_axc_g.png)
The AXC - Garage medium-pressure axial fans are two fans connected in series with counter - rotation of the impellers to achieve higher pressures. The AXC-Garage fans are suitable for ventilation in underground and above-ground garages at a constant temperature of 55 °C.
The AXC fans are available only on request and are made to order according to your individual requirements and needs. If you are interested in any of these fans, please send an inquiry to our email with the required operating point of the fan, or contact us by phone.
Variants:
AXC Garage - Fan for temperatures of up to 55 °C
AXC F Garage - Thermo fan for continuous operation up to 55 °C and for 120 minutes up to 400 °C
AXC B Garage - Fan for heat and smoke extraction for continuous operation up to 55 °C and for 120 minutes up to 300 °C
AXC (B)/ AXC (F)
![AXC (B)/ AXC (F)](https://en.ventilatory.net/media/catalog/category/axc-b-f-hlavni.jpg)
The AXC (B)/ AXC (F) medium pressure axial fans are smoke extract fans with a temperature resistance of 300°C / 400°C for 2 hours. They have adjustable blade angle and allow indoor and outdoor mounting, horizontal and vertical. They are equipped with IE3 motors, have IP 55 protection and insulation class H.
The AXC fans are on demand only and are made to order according to your individual requirements and needs. If you are interested in any of these fans, please send an enquiry to our email with the required fan operating point or contact us by phone. Fans can be supplied with a soundproof box on request.
Variants:
AXC (B) - Fan for temperatures up to 300°C for 2 hours
AXC (F) - Fan for temperatures up to 400°C for 2 hours