How to Choose an Explosion-Proof Fan (ATEX)
Selecting an explosion-proof fan is not just a matter of airflow and pressure. If flammable gases, vapours, mist or dust may occur in your operation, you need to choose equipment according to ATEX requirements. That is why terms such as ATEX fan, Ex fan or fan for hazardous areas are commonly used in practice. In this article you will find a clear procedure for choosing a safe and technically suitable model for a specific application.
You can find all available models in the Explosion-proof fans category. If you already know what design you are looking for, you can go directly to inline explosion-proof fans, wall-mounted explosion-proof fans or roof explosion-proof fans.
1. When you need an explosion-proof fan
An explosion-proof fan is necessary wherever an explosive atmosphere may occur. Typical operations include working with solvents, petrol vapours, alcohols, chemicals, hydrogen or combustible dust. Common applications include spray booths, chemical plants, solvent storage, battery rooms, woodworking production, food technologies, silos, dust extraction or technical rooms with a risk of flammable mixtures.
A standard fan is not designed for such an environment. In ATEX applications, you need to address not only performance, but also construction safety, surface temperatures, material design, grounding and compatibility with the specific zone.
2. First determine whether you are dealing with gases, vapours or dust
The basic question is: What exactly in your operation can create an explosive atmosphere? The entire selection process depends on that.
- Gases, vapours and mist – typically chemistry, paint shops, solvent stores, fuel handling, hydrogen.
- Combustible dust – typically wood, flour, sugar, feed, plastic or metal dusts and some technological operations.
This distinction is essential because gaseous atmospheres are assessed differently from dusty atmospheres. Only then does it make sense to deal with the zone, equipment marking and the specific fan design.
3. Determine the ATEX zone
Without knowing the ATEX zone, the fan cannot be selected correctly. The zone determines how often and how long an explosive atmosphere may occur at the installation site.
- Zones 0, 1, 2 – for gases, vapours and mist.
- Zones 20, 21, 22 – for combustible dust.
Put simply, the higher the risk and the more frequent the occurrence of an explosive atmosphere, the stricter the equipment requirements. The ATEX zone is usually determined by a designer, safety engineer or the person responsible for area classification. If you do not know it, do not start selecting a specific fan from performance data, but from this information.
4. Check the fan's ATEX marking
Once you know the type of medium and the zone, the marking of the fan itself comes next. On the nameplate or in technical documentation you may find, for example, a marking such as II 2G Ex h IIB+H2 T3 Gb. This marking tells you which environment the fan is intended for, for which media group and what maximum surface temperature the equipment allows.
The most important parts in practice are mainly these:
- Environment group – for industrial operations outside mining you typically encounter group II.
- Category / intended use – it must match the zone in which the fan will be installed.
- Gas group – for example IIA, IIB, IIC or IIB+H2 depending on the specific medium.
- Temperature class – for example T3 or T4, i.e. the maximum surface temperature of the equipment.
On our website, for example, you can find the DKEX and RVK ranges, for which certification for hydrogen is also stated. This is important in applications where standard IIA or IIB design is not sufficient.
5. Calculate the required airflow and pressure loss
Only after the ATEX parameters are resolved does classic ventilation engineering come into play: what airflow you need and what pressure the fan has to overcome. Without that, it is not possible to choose the right type or size of fan.
- Airflow (m³/h) determines how much air you need to extract or supply.
- Static pressure (Pa) determines the resistance the fan will overcome in ductwork, filters, dampers, grilles or technology.
If you have longer ductwork, more bends, filters or a more complex route, a centrifugal explosion-proof fan is usually more suitable. By contrast, for simpler exhaust or supply air, an axial design may be appropriate.
6. Choose the right fan construction
According to the installation method and operation, you choose among several basic constructions:
Inline explosion-proof fans
These are designed for direct installation into the HVAC route and make sense where the fan is mounted directly into the duct. You can find the full filtered range here: inline explosion-proof fans. Specific ranges:
- TCBT Ex – axial inline explosion-proof fans
- EX – explosion-proof centrifugal inline fans
- RVK – explosion-proof plastic inline fans
- DKEX – explosion-proof centrifugal fans for round and rectangular ductwork
Wall-mounted explosion-proof fans
Suitable for direct wall installation and simple air extraction from a room. Filtered range: wall-mounted explosion-proof fans. Typical range: E-ATEX.
Roof explosion-proof fans
Used where you need safe exhaust through the roof of a building. Filtered range: roof explosion-proof fans. Typical range: TCDH Ex.
Centrifugal explosion-proof fans for higher pressure
If you need to overcome higher pressure losses or are solving technological extraction, a centrifugal design makes sense. Good examples are CMS ATEX or DKEX.
7. Also address voltage, IP rating, material and control
With explosion-proof fans, it is often not only performance that decides, but also electrical and construction details. Your website also provides useful filters that can speed up the selection significantly.
When deciding, I recommend checking:
- voltage and motor type – 230 V, 400 V or other design according to the project,
- IP protection – important especially in dusty, humid or outdoor environments,
- fan material – metal, brass parts, conductive plastics or special materials according to the medium,
- control option – always only in accordance with the Ex design and the manufacturer's recommendation.
8. The most common mistakes when selecting an ATEX fan
- selection based on airflow without knowing the ATEX zone,
- confusing gas and dust environments,
- ignoring the gas group or temperature class,
- underestimating the pressure loss of the duct route,
- incorrectly selected control or accessories outside the Ex regime,
- assuming that “explosion-proof” means universal use in all Ex environments.
The last point in particular is very common. There is no single universal ATEX fan for all situations. The correct model must be selected according to the specific medium, zone, temperature and installation method.
9. What to prepare before an enquiry
If you want a quick and correct proposal, prepare these details:
- ATEX zone,
- type of medium – gas, vapours, mist or dust,
- gas group or other project requirements,
- required airflow in m³/h,
- estimate or calculation of pressure loss in Pa,
- required installation method – inline, wall-mounted, roof,
- voltage, IP protection and operating temperature.
The more accurate your input data is, the faster the correct and safe fan can be selected.
Frequently asked questions
What is the difference between a standard fan and an explosion-proof fan?
An explosion-proof fan is intended for hazardous areas and its construction, marking and use must comply with ATEX requirements. A standard fan does not belong in such an environment.
Do I need to know the zone for selection?
Yes. Without knowing the ATEX zone, it is not possible to determine correctly which Ex fan design is safe for the given operation.
Are there also fans for hydrogen on the website?
Yes, the website includes, for example, the DKEX and RVK ranges, for which certification for hydrogen is also stated.
Where can I find the full range of Ex fans?
You can find the complete range in the Explosion-proof fans category.
Need help with selection? Start in the Explosion-proof fans category and filter by installation type, construction or technical parameters. If you are not sure about the ATEX zone or the suitable design, prepare the basic technical data and consult the enquiry with a designer or technician.