Panel filters

Panel filters

- filter class G4 - F8 according to EN 779
- high performance in relation to price, non-standard dimensions according to customer's requirements
- large filtration area formed by V-shaped folds reinforced with Al grid with 98% free area
- low weight, small installation depth, small transport volume

DESCRIPTION OF PANEL FILTERS

The panel filters are made of filter material that is pleated, impregnated and reinforced with an Al grid with 98% free surface area. The optimally spaced filter material folds are fixed and sealed in a rigid cardboard frame with the HOT-MELT system. For higher airflow rates, the filter is reinforced on the outlet side with reinforcement.

VARIANTS OF PANEL FILTERS

We supply dimensions according to customer requirements. The filters are available in: high strength plastic frame and metal reinforcements, metal frame and metal reinforcements or cardboard frame. Filter materials from G4 to F8.

PANEL FILTER APPLICATION OPTIONS

Typically, the filters are used to capture and retain coarse dust particles (filtration class G4) and extend the life of secondary filters or to capture and retain fine dust particles (filtration class F5-F8) in most air conditioning units. For higher humidity we recommend the use of a high strength plastic frame.

FILTER REPLACEMENT AND DISPOSAL

The recommended final pressure drop is 200 - 300 Pa. To save energy costs, the final pressure drop should not be exceeded. It is recommended to dispose of used filters by pyrolysis in incinerators or landfill, metal parts are used for secondary processing.

Send us a request info@ventilatory.net or contact us by phone: +420 417 565 655 Send request

Set Descending Direction

1-25 of 38

Page:
  1. 1
  2. 2

Set Descending Direction

1-25 of 38

Page:
  1. 1
  2. 2

AFR

AFR

The AFR filters are designed for the DOMEO, EASY, EHR, IDEO and ROVENTO heat recovery units. The AFR filters vary depending on the filtration class (G4 / M5 / F7) and on the type of the heat recovery unit. The filters are always compatible only with the marked ventilation unit.

 

MPRO

MPRO

MPRO are panel filters for Rotovex ventilation unit with filtration class F5/F7.

 

KS MPP

KS MPP

KS MPP are frame filters designed for the separation of fine dust in public areas of healthcare, laboratories, air conditioning and air handling units, etc. The filter material of KS MPP filters is embedded in a plastic or cardboard frame. KS MPP panel/plate filters are supplied with filtration class M5 / M6 / F7 / F8 / F9. Filter dimensions according to customer requirements, filter depth from 30 to 96 mm.

 

KS PL

KS PL

KS PL are frame filters designed for under-ceiling air conditioning units and intake equipment. The KS PL filters have a frame made of galvanized sheet metal, on the clean air side the filter medium is covered by a protective zinc grille and on the other side it is fixed with a spring pin. Depending on the filtration requirements, the KS PL filters can be supplied with fibreglass media or with special KS CARB media with activated carbon. The KS PL panel/plate filters are manufactured in dimensions according to customer requirements with filtration class G2 / G3 / G4 / M5.

 

KS PR

KS PR

KS PR are frame filters designed for filtration of coarse and fine dust in air conditioning units of production halls, office premises, telecommunication exchanges, medical facilities, airport halls, etc. The KS PR filters are embedded in a solid frame made of galvanized sheet metal with metal separators. The advantage is the possibility of changing the filter media and thus very low operating costs. The panel / plate filters are manufactured in dimensions according to customer requirements, with filtration class G2 / G3 / G4 / M5.

 

KS MPS

KS MPS

KS MPS are frame filters designed as a second or only filtration stage for air conditioning and HVAC units. The KS MPS panel / plate filters are manufactured in filtration classes M6 / F7 / F9 with an efficiency of 60 - 95%.

 

KS W

KS W

KS-W are frame filters designed for filtration in public areas, laboratories, hospitals, etc. The filter material of the KS-W panel filter is made of folded synthetic filter fibre, embedded in a cardboard frame with a cardboard grid and sealed with a hot-melt system. When filters are used in HVAC systems with higher airflows, the filters are reinforced with a spacer. The frame can be made from galvanised sheet metal or plastic on request. The plate filters are manufactured with a filtration class of G4 and a medium separation efficiency of up to 90%. Filter dimensions according to customer's requirement on request.

 

MFRT

MFRT

Replacement grease filter MFRT designed for MFLT filter cassettes. The MFRT grease filters are designed as a replacement for insertion into the MFLT filter cassette.

 

MFRU

MFRU